Updated November 2026
To start a Firman dual fuel generator, you set the fuel selector to the fuel you plan to use, check oil and fuel, turn the engine switch on, set the choke, and pull or press the start control. Most units start within a few pulls on gasoline and need a short warm-up on propane. The steps below cover both fuels, along with the mistakes that cause most no-start complaints.
Prepare the Generator Before You Start
Put the unit on a flat surface at least 20 feet from doors, windows and vents, with the exhaust pointed away from the house. Confirm the oil level is at the full mark on the dipstick, since most Firman units shut down on low oil. Make sure nothing is plugged into the outlets and the main breaker is off.
Shopping for one? See our guide: 6 Best Firman Dual Fuel Inverter Generators Compared (2026).
Starting on Gasoline
- Set the fuel selector to gasoline.
- Turn the engine switch to ON.
- Move the choke to the closed position for a cold start.
- Pull the recoil starter firmly, or press the electric start button if your model has one.
- Once the engine fires, move the choke to open as it warms, usually within about a minute.
Starting on Propane
Propane is the easier fuel to start in cold weather because it vaporizes before it reaches the engine, but it still needs correct setup. Connect the hose from a 20-pound cylinder to the regulator, open the cylinder valve fully, then follow the same steps as gasoline with the fuel selector set to propane. If the engine turns over but won’t catch, confirm the cylinder is not nearly empty, since low pressure is a frequent cause.
Troubleshoot a Hard Start
If the engine cranks without firing, check fuel first, then spark, then air. Stale gasoline older than about 30 days is the most common culprit, and owners often report that draining the tank and replacing the fuel solves the problem. Leave the choke closed a little longer on a cold morning, but open it once the engine catches, or it will flood and smoke.
- Check that the spark plug wire is firmly connected.
- Confirm the air filter is clean, since a clogged filter starves the engine of air.
- If the unit won’t start after several attempts, stop and let it rest a few minutes so the spark plug does not stay soaked with fuel.
Common Mistakes When Starting a Firman Dual Fuel Generator
- Switching the fuel selector while the engine is running, which can cause stalling.
- Leaving the choke closed after the engine has started, which floods the carburetor.
- Running the unit with the oil just above the low mark.
- Starting indoors or in a garage, even briefly, because carbon monoxide builds up fast.
- Using gasoline stored over the winter without a stabilizer.
Recommended Gear
A fuel stabilizer helps when the generator sits between uses, because it slows gasoline breakdown that clogs the carburetor. View on Amazon
A propane cylinder gauge or scale lets you confirm how much fuel remains before you need to start the unit during an outage. View on Amazon
FAQ
Does a Firman dual fuel generator start easier on gas or propane?
Propane usually starts more reliably in cold weather because it does not gum up the fuel system the way old gasoline can. Gasoline starts quickly in mild conditions when the fuel is fresh.
Why won’t my Firman generator start after sitting for months?
Old gasoline is the usual cause, so drain the tank or replace the fuel, then check the spark plug and air filter. Keeping the unit on a fuel stabilizer prevents most of these problems.
Can I start the generator with the choke open?
Cold engines generally need the choke closed to start, while a warm engine often starts with it open. If you are unsure, consult the owner’s manual or a qualified small-engine technician.
Conclusion
Starting a Firman dual fuel generator comes down to the right fuel selection, correct choke use and fresh fuel. Once you have run through the steps a few times, the process takes only a minute. For any electrical connection to your home, consult a licensed electrician.